BRAVE – user guide
5.5 System parametres
Acoustic signalling (confirmation, error, empty
memory, call termination...) (0/1)
In default the stages of door intercom are acoustically signalling. By parametr
„z“ you can switch off this signalling. Possible values are
z=0 – signalling is off
z=1 – signalling is on
Acoustic signalling off hook/on hook
(0/1/2)
In default is signalling pick up and hang up of the line. If you identify some
problems at certain PBXs you can switch it off by parametr „v“ . The possible
values are:
v=0 – signalling OFF HOOK / ON HOOK is off
v=1 – signalling OFF HOOK / ON HOOK is on (type 1)
v=1 – signalling OFF HOOK / ON HOOK is on (type 2)
Acoustic signalling knocking to call (0/1)
In default it is switch off. By activation of this feature you can identify at PBX
calling from door intercom just up knocking into call. Possible values are:
u=0 – knocking to call is off
u=1 – knocking to call is on
Powering from external power supply 12V
(DIP 3,4) (0/1)
In version /C only or at version (C) .
In default external power supply is OFF.
Activation has a sense only in cases when door intercom should make some
operation during stand by mode – relay activation. Relay in mode m=7 allows
permanent closing even after call termination. Relay mode m=8 allows
activation up DAY/NIGHT mode settings even after call termination. In those
cases you have to provide external power supply to dont flow current at hanged
up line. The DIP switch 3 and 4 must be in position „on“ to activate this parametr
w=1 . Deactivation - w=0.