BRAVE user guide
40
Parametr
Value
description
Default
65
z
Acustic signalling of relay activation (0/1)
0
In default the activation is off z=0. Usually you can use this fetaure for DC power
supply 12V. Then when el.lock is released you dont hear „buzzing“ so visitor
doesnt know that el.lock is released. When you activate this feature z=1 then
during relay activation you hear special sounds simulating relay activation.
Note.1 This feature is available for relay mode m=1, m=5 only.
Note.2 For relay activation with 2 pulses the acoustic signalling sounds during
whole time of sequence. (even in space between pulses)
Parametr
Value
Description
Default
66
i
Suppression of DTMF reception from
microphone (0/1)
0
In default the suppression of DTMF reception from MIC is off i=0. Due this you
can activate relay by personal dialler without ringing to person inside building. To
increase security you can activate suppression of DTMF reception from
microphone i=1 and due this protect entrance of persons who provided record of
DTMF code for door opening.
Parametr
Value
Description
Default
67
b
BabyCall call without neccessity programm
phone number (0/1)
0
In default is switch off b=0. By activation this feature b=1 is cancelled acoustic
signalling of empty memory. After pushing of button with empty memory you get
just beep (confirmation) and call is established as normal dialled number
Caution: first 10sec of call is not active tone detector (it waits on reaction of PBX
and number dialling by PBX)
Parametr
Value
Description
Default
6*
t
delay start for PBx´s with line testing
(Siemens) (0/1)
0
In default is switch off t=0. By activation this feature t=1 is processor going to
„sleep mode“ after line connection and after 3sec the door intercom makes
initialization. It delays line picks up after line ( voltage) connection activation
status / PBX restart. When this feature is not efficient and PBX still evaluate the
line into „failure“ mode“ then you have to use external power supply put DIP
switch 3 and 4 to position "on" possible at version /C (C) only. It is the same
like using Best Box option.