IPDP - installation and operating instructions
delay” and after that is activated Relay 2 automatically for certain time
“time closing 2”. Then Door phone hangs up.
.
Note: The only relay 1 can be activated from phone and all sequence started.
Besides that the relay 2 can be separately activated from buttons by password.
2. Password (code) to activate relays from Door phone ( by buttons), [2 to 6
digits]. There is totally 6x codes which are control by DAY/NIGHT mode
setting. The code is inserting by Door phone buttons combination ( 1 or 2
buttons only). Relay activation is influenced by programmed relay mode as
same as DAY/NIGHT mode. When you use mode of dial 2 groups the
door phone is permanently in mode DAY.
3. Code by phone for relay activation [2 digits]. You can programm the same
code for both relays. Then both relays will be activated at the same time
when you dial the code. We recommend to programm the same code for
relay activation as same as door phone hanging up (page 33).
4. Closing time for which is relay activated (on) [2 digits, 01-99]
5. Permitt / Prohibit to control relay during incoming call.
6. Delay time between activation relay 1 and relay 2 when is used mode 5 at
relay 2, m=5 (gradual opening) , [2 digits 01-99]
7. Default factory setting. After making changes click on button „ save
changes