40
Generators
All Models
Gas Inlet Pressure:
0.5 to 2 PSI Inlet Pressure (Contact Alpha
Engineering for additional supply resources)
Ign Charger Voltage: 13.5Vdc
Ign Charger Current: 6A max.
Remote Interface Length:
75ft typical. Distance depends upon installation,
de-rating and wire gauge.
Agency Compliance:
UL1778, UL2200, NFPA 37/54/58 and 70, CSA
C22.2 No.107.1, EMC/FCC Part 15 Class A
Fuel System, Controls
and Monitoring:
The controls and fuel system meet applicable
sections of NFPA 37, 54 and 58 for automatic
unattended operation of remotely located
generators. Full System Control and Status
Monitoring included.
Sensors: Gas hazard, pad shear, water intrusion and tamper
Safety Shutdowns:
Low oil pressure, over temp, low fuel pressure
shutdown (propane only), water intrusion,
pad shear, gas hazard (propane or natural gas),
over-speed, over-crank
Optional Feature:
Cold Start Kit: provides additional starting
capability at temperatures below -18°C / 0°F
AlphaGen Configuration Options
CE-3x2 3.5 or 5kW CE-9x2 3.5 or 5kW
CE-3/9G Propane Storage for Generator
(For 3.5 and 5kW)
PN-6x 7.5kW
(PN-6x is not compatible with CE-3/9G)
AlphaGen Curbside
Output Rating: 3.5kW 5.0kW 7.5kW
DC Output Voltage:
39V ±0.5V @ no load 36V configuration 39V ±0.5V @ no load 36V configuration 52V ±0.5V @ no load 48V configuration
52V ±0.5V @ no load 48V configuration 52 ±0.5V @ no load 48V configuration 104V ±0.5V @ no load 96V configuration
DC Output Load Regulation: 0.5V 0.5V 0.5V
Output Current: 39V @ 90A max. / 52V @ 67A max. 39V @ 128A max. / 52V @ 96A max. 52V @ 144A max. / 104V @ 72A max.
Engine: 398cc, Air cooled, Single OHV 10.5hp (using natural gas fuel)
RPM (Variable Speed): 2800 to 3600RPM 2800 to 3600RPM 2800 to 3600RPM
Acoustical Noise
dBA 10' @ 100% Rated Load: 68.7 68.5 70.3
dBA 20' @ 100% Rated Load: 63 62.5 64.3
dBA 10' @ 70% Rated Load: 68.3 66.9 66.4
dBA 20' @ 70% Rated Load: 62.6 60.9 60.4
Models: CE-3x2 CE-9x2 CE-3x2 CE-9x2 PN-6x
Dimensions
H x W x D (in/mm):
44 x 26 x 24 /
1117.6 x 660.4 x
609.6
52 x 26 x 24 /
1320.8 x 660.4 x
609.6
44 x 26 x 24 /
1117.6 x 660.4 x
609.6
52 x 26 x 24 /
1320.8 x 660.4 x
609.6
39 x 39.3 x 24 / 914 x 998.2 x 609.6
(57 x 39.3 x 24 / 1447.8 x 998.2 x 609.6
with optional pedestal)
Weight (lb/kg): 383 / 174 413 / 187 383 / 174 413 / 187 338 / 174 (370 / 168 with optional pedestal)
APU Fuel Consumption
Natural Gas (1000BTU/Ft.
3
): 60ft
3
/hr 80ft
3
/hr 150ft
3
/hr
Propane Gas (2520BTU/Ft.
3
): 0.82gal/hr - 30ft
3
/hr - 3.46lb/hr 1.10gal/hr - 40ft
3
/hr - 4.62lb/hr 1.48gal/hr - 50ft
3
/hr - 6.24lb/hr
Exterior Surface Temperature: 65°C / 149°F max (meets requirements of UL/CSA)
AlphaGen CE3x2-3G
> Cost-effective extended runtime solution
for broadband powering applications
> Quiet operation, small size and low profile
allow for easy installation in populated areas
> Eliminates the large quantities of batteries
otherwise required for extended runtime
AlphaGen
Curbside