Alpha Technologies IPDP - 00C Manual de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 29
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
16
Parameter
Value
Description
Default
32
hhhhhh
External access code in DAY + NIGHT
mode
-
33
hhhhhh
External access code in DAY mode
-
34
hhhhhh
External access code in NIGHT mode
-
hhhhhh password for relay closing from buttons [2 to 6 digits]
The 3 passwords are controlled by Day/Night; the combination is entered using
the unit buttons. It is influenced by the setting of Relay mode and Day/Night
switchover. When set to 2-group mode the unit is permanently in DAY mode.
Follow these rules when choosing password combination:
Select passwords carefully, to prevent their discovery from wear on
buttons caused by frequent use.
Select the first password button from infrequently-used buttons for
direct dialling (-extends choice time)(-not valid for keyboard).
Note: The switchover to Day/Night mode remains set in unit even after line
disconnection.
Parameter
Value
Description
Default
35
aa
Internal access code
55
aa command from phone to relay closing [2 digits]
It is recommended to set the same command for Internal Access Code and
End Call (parameter 43) aa=bb.
Parametr
Value
Description
Default
36
ss
Relay closing time
05
ss duration of relay closing [2 digits 01-99]
Parametr
Value
Description
Default
37
pp
Time between 2 impulses [sec]
05
pp duration of delay between 2 impulses of relay [2 digits 01-99]
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 28 29

Comentarios a estos manuales

Sin comentarios