BRAVE – user guide
Example: command to activate relay1 with 1 pulse *8, command to hang up *8 and
command for activation relay2 with 2 pulses *9.
Dial: 352*8 ♫ , 432*8 ♫ , 362*9 ♫.
You are in communication with door intercom unit. Dial command for open sliding gate 9.
First pulse starts sliding the gate and second pulse stop it. The size of spot for person
entrance is according time between each pulses (parametr 30). After person etnering you
dial 8. The door intercom makes one pulse and hang up. Sliding gate is closing.
time ss [sec] activation relay r for time t1/t4
(00-99)
r – relay number [1-2]
ss – time t1 / t4 for which is relay closed 1 / 2 [2 digits 00-99], where time 00
means 0,5sec
Control relay r during incoming call
(0/1)
r – relay number [1-2]
p – parametr which says permitted p=1 or forbidden p=0 control relay during
incoming call
To prohibit control of relay during incoming call has a sense for example by
relay2 in mode 1 by which you control sliding gate opening where door intercom
open the gate and after car passing the gate is closed. Then control by phone
could make unwillingly permanent gate opening.
time xx [sec] between activation relay 1
and 2 in mode m=5 - time t3
(01-99)
xx – time t3 between activation relay 1 and 2 when mode m=5 is setup
(progressive opening) [2 digits 00-99] ], when time 00 means 0,5sec
time zz [sec] between pulses when is
closing for 2 pulses relay r - time t2/t5
(00-99)
r – relay number [1-2]
zz – time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits
00-99], where 00 means 0,5sec