Alpha Technologies Brave Slim - LC/C Guía de usuario Pagina 37

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 57
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 36
BRAVE user guide
37
Parametr
Value
Description
Default
54
z
Hanging up time during REDIAL (1-5)
2
z time [sec] for which door intercom hangs up before pick up for REDIAL
(button push during call, busy tone detection) [range 1-5]
Parametr
Value
Description
Default
55
z
Time before start dialling (1-5)
1
z time [sec] after door intercom picks up and before start dialling [range 1-5].
This time is different for every PBX but usually all PBXs accepts dial within 2
seconds after line is picked up.
Parametr
Value
Description
Default
56
hh
Number of rings before hang up (04-99)
12
h after dial termination calculate number of CRT (control ring tones). When
number is higher than hh then hang up [range 04-99]. Dial is repeated in
case of 2 groups mode.
Parametr
Value
Description
Default
500
x
Middle frequency of tones detector (1-0)
3 (375-475Hz)
501
y
Number of busy tones (2-0)
4
502
z
Time of permanent tone duration (1-5)
3 (3s)
x middle frequency of tones detector is suitable when PBX signalling is
unusual:
y minimal number of busy tones neccessary for
detection [2-0], where 0 means 10 busy tones
z minimal time of permanent tone duration (for dial
tone detection on PBX) [1-5 sec]
Parametr
Value
Description
Default
frequency
[Hz]
x - dial
275-375
1
325-425
2
375-475
3
425-525
4
475-575
5
525-625
6
575-675
7
625-725
8
675-775
9
725-825
0